11/6/2023 0 Comments Hanging scaffold nycReferences to related job numbers (e.g.For a supported scaffold, structural members, as well as the founding of the scaffold, including but not limited to sidewalk sheds, floors, roofs, or ground.For a suspended scaffold, the location of the scaffold during out of service periods, and if the scaffold will not be lowered to the street, sidewalk shed, building setback, equivalent adequate structure, or ground during out of service periods, how the scaffold will be secured while work is not being performed.For a suspended scaffold, ropes, number of clips, and counterweights, outrigger beams, c-hooks, or other support devices, blocking, saddles, or equivalent, and the rated load of the scaffold motor (hoist) as established by the manufacturer.Temporary construction, such as platforms, runback structures, other scaffolds, mast climbers, cranes, derricks, hoists, horizontal netting, cocoon systems, climbing formwork, sidewalk sheds, fences, and barricades that may present interference for the scaffold.Platform levels, support centers, and offsets, along with the maximum number of levels to be loaded simultaneously and the maximum loads to be imposed.Any hoisting equipment located on the scaffold.The effect of wind on the netting shall be accounted for in the design of the scaffold Netting with specific type and manufacturer indicated, overhead protection, or any other equipment attached to the scaffold.Any temporary or permanent structural modifications required to the base structure.Connections and attachments to the base structure, including but not limited to anchorages, fastenings, tie-ins, tie-backs, and lifelines.The scaffold and location of the scaffold.Where design is required by this section, the drawings shall be specific to the site and shall, at a minimum, include a plan view and an elevation view, with full dimensions, detailing: Suspended scaffold meeting the requirements of Item 2 of these exceptions that is usedĮxclusively for sign hanging work may be designed by a licensed sign hanger. In lieu of a registered design professional or a licensed rigger, a two-point, single tier,.The top of the outrigger beam or suspension member support structure is The distance from floor or roof on which the support structure is located to.The scaffold will not be loaded, or designed to be loaded, in excess of 75 pounds.Is not anchored to the building or structure, other than tiebacks and The scaffold or scaffold outrigger beam or suspension member support structure.May be designed by a licensed rigger provided Items 2.1 and 2.2 are complied withĪnd either Items 2.2.1 or 2.2.2 are complied with: In lieu of a registered design professional, a two-point, single tier, suspended scaffold.Design is not required for a single tier nonadjustable suspended scaffold whose.Where the scaffold has a height-to- base ratio (including outriggers supports, if used) of more than four to one (4:1), it is restrained in accordance with Section 3314.9.1.Side-arm or end-arm scaffold brackets are used exclusively for the support of workers and.The scaffold is less than 40 feet (12 192mm) in height.a light duty scaffold, a medium duty scaffold, or a heavy duty scaffold) The scaffold will not be loaded, or designed to be loaded, in excess of 75 pounds per square foot (366.15 kg/m 2 ) (e.g.No hoisting equipment with a manufacturer's rated capacity greater than 2,000 pounds (907 kg) will be located on the scaffold. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |